GOLDLINE AUTOMATIC VOLTAGE STABILIZER
The highly fluctuating A.C.Mains supply is a
very common phenomenon in India and difficulties caused by
them are known too well need not be enumerated. With the
emergence of sophisticated equipments, the need for a stable
input supply is a basic necessity, in the absence of which
many sophisticated equipments do not give optimal performance.
On the contrary, in many equipments, unsteady supply
conditions result in total breakdown of sensitive and
sophisticated equipments, leading to heavy down time and
costly repairs and maintenance of the equipments. The hope of
getting a stable supply is very remote in our country, and
keeping this in view, GOLDLINE Automatic Voltage
Stabilizer.
APPLICATIONS:
GOLDLINE
Automatic Voltage Stabilizer have many applications. To name a
few
• For Home appliances
T.V. V.C.R, FRIDGE, WASHING MACHINE, OVEN
HEATER,AUDIO SYSTEMS, COOLER, AIR CONDITION, MIXI, MOTOR etc.
FEATURES:
The
following are built-in features of each and every Automatic
Voltage Stabilizer
• Fully solid state control
circuitry, using high stability industrial grade silicon Semi-
conductors. Relays are totally eliminated, reducing any chance
for failures in the field.
• Efficiency better than 95% at full
load
• NILwave form distortion
• Mode of
correction by power relays eliminates any failure in the
field.
• No effects of load power factor
•
Inter-Changeable plug in control card and module.
•
Unaffected by change in supply frequency between 45 to 63
Hz.
• Large short-time over-load capacity, ideally
suited for high starting current of inductive
motors.
• No phase shift.
• Low Internal
impedance.
• Under voltage and over voltage
cut-off
• High Speed correction.
• Built in
time delay prevents immediate restart and chattering in case
of power interruptions and affords balancing time for
compressor.
ADDITIONAL FEATURES
The following
additional features can be provided against specific enquiries
at an extra cost.
• output cut-off in case the output
voltage goes beyond the setlimits. In both the above cases,
time delay can be provided so as to avoid problems caused by
erratic tripping.
• M.C.B. protection on the
input.
• Volt meters and Ammeters
• Alarm to
indicate input high/low and output high/low.
• Stand
and Voltage Level Indicators.
SPECIFICATIONS:
Goldline “Automatic Voltage Stabilizers are mass manufactured in the following ranges.

-
300V300 V.A.Extra Boost
Capacity :300VA, High Voltage Cut off :Above 285 Output Voltage :200V to 250V (Input from 170v to 280V) Working Range :90 to 285 V Input Application :One T.V.V.C.R & Stereo
Capacity :300VA High Voltage Cut off :Above 280 V input Output Voltage :200V to 245V (input from 100v to 275V) Working Range :70V to 280V input Application :One T.V.,V.C.R., Stereo
500 V.A.
Capacity :500VA High Voltage
cut off :Above 270V input Low Voltage cut off :Below 145V
input Output Voltage :200V to 245V (Input from 170V to 260V)
Time Delay : 2 to 4 minutes Application :Regrigeration (Max
1/6 HP Compressor)
500 VA wide range
Capacity :500VA High Voltage Cut off :Above 285V input Low Voltage cut off :Below 120V input Output Voltage :200V to 245V (Input from 140V to 285V) Time delay :3.5 minutes
1KVA
Capacity :1KVA High Voltage Cut
off :Above 270V input Low Voltage cut off :Below 145V input
Output Voltage :200V to 245V (Input from 170V to 260V) Time
Delay :3.5 minutes Application :Deep Freezer/Water Cooler
Double Door Double Compressor Refrigerator
1KVA Wide Range
Capacity :1KVA Wide Range High Voltage Cut
off :Above 285V input Low Voltage cut off :Below 120V input
Output Voltage :200V to 250V (input from 140V to 280V) Time
Delay :3.5 minutes Application :Deep Freezer/Water Cooler
Double Door Double Compressor Refrigerator
1.5KVA
Capacity :1.5KVA High
Voltage Cut off :Above 270V input Low Voltage cut off :Below
145V input Output Voltage :200V to 245V (Input from 170V to
260V) Time Delay :3.5 minutes Application :0.5 Tonne AC(6.6
AMP max)

4 KVA STANDARED 1975/-
4 KVA DELUX 2950/-
2,3,4 & 5 KVA DELUX
Capacity
:2,3,4 & 5 KVA High Voltage Cut off :Above 275V input Low
Voltage cut off :Below 145V input Output voltage :200V to 245V
(Input form 165V to 270V) Time Delay :3.5 minutes
Application:
2KVA : 0.75 Tonne AC 8.8 AMP max.
3KVA : 1 Tonne AC13.6 AMP max.
4KVA : 1.5 Tonne AC 17.6 AMP max.
5KVA : 2 Tonne AC 22.6 AMP max
- 4 KVAWide Range
Capacity :4KVA
High Voltage Cut off :Above 285 V input
Low Voltage cut off :Below 120V input
Output Voltage :200V to 245V
(Input from 140V to 285V)
Time Delay :3.5 minutes
Application :1.5TONNE (17.8 AMP max)
- 4 KVA Special boost
Capacity :4KVA
High Voltage Cut off :Above 285 V input
Low Voltage cut off :Below 100V input
Output Voltage :200V to 245V
(INPUT FROM 120V TO 285V)
Time Delay :3.5 minutes
Application :1.5TONNE AC (17.8 AMP max)
11 . 4 KVAWide Range
Capacity :5KVA
High Voltage Cut off :Above 285 V input
Low Voltage cut off :Below 120V input
Output Voltage :200V to 245V
(INPUT FROM 140V TO 285V)
Time Delay :3.5 minutes
Application : 2 TONNE AC (22.5 AMP max)
12. 4 KVA Special boost
Capacity :5KVA
High Voltage Cut off :Above 285 V input
Low Voltage cut off :Below 110V input
Output Voltage :200V to 245V
(INPUT FROM 135V TO 285V)
Time Delay :3.5 minutes
Application : 2 TONNE AC (22.5 AMP max)
Marketed by